A. O. Smith UPVA-110Y 1**

A. O. Smith UPVA-110Y 1** is in the DOE listing as of Oct 26, 2026.

It has a certified UEF of 0.94 and a certified flow of 1.0 gal/min at a 67°F rise.

Its advertised flow of 1.0 gal/min at a 67°F rise from A. O. Smith matches the certified 1.0 gal/min at a 67°F rise (Read Oct 4, 2026).

  • Electric tankless water heater
  • 1 listed model

ENERGY STAR certification does not cover this type of water heater.

Certified and advertised figures

Flow at a 67°F rise
1.0gallons per minuteCertified
Advertised flow
1.0gallons per minuteA. O. Smith, at a 67°F rise
UEF
0.94Uniform energy factor

Flow where you live

The heater gives less flow when colder incoming water needs a bigger rise.

Cold water
Cold water must be at least 10°F colder than the hot water setting.
Flow estimate
The estimate uses the lowest certified flow among the listed models. It is about 1.0 gal/min at a 70°F rise.

Flow limits

  • The estimate excludes the flow needed to turn the heater on, heat lost in pipes, and installation.
  • Cold water from a well or long pipe run can differ from the temperature you enter.
  • Without a stated flow limit, estimates for warmer water may exceed the heater’s actual flow.

Advertised and certified figures

A. O. Smith UPVA-110Y 1**: advertised and certified
A. O. Smith UPVA-110Y 1**: advertised and certified UEF: advertised 0.93, certified 0.94. Flow: advertised 1.0 gal/min, certified 1.0 gal/min (advertised at a 67°F rise, certified at a 67°F rise). UEF Advertised 0.93 Certified 0.94 Flow · advertised at a 67°F rise, certified at a 67°F rise Advertised 1.0 gal/min Certified 1.0 gal/min
A. O. Smith UPVA-110Y 1**: advertised figures, where and when read
FigureAdvertisedCertifiedAdvertiserRead
UEF 0.93 0.94 A. O. Smith Read Oct 4, 2026
Flow 1.0 gal/min at a 67°F rise 1.0 gal/min at a 67°F rise A. O. Smith Read Oct 4, 2026

See how advertised flow compares across tankless models

Certified figures by listed model

A. O. Smith UPVA-110Y 1**: certified figures by listed model
Model numberUEFFlow at a 67°F rise (gal/min)Recovery efficiencyDraw pattern
UPVA-110Y 1**0.941.098%Very small

UEF is the uniform energy factor. A dash means the model has no such figure.

It warms 1.0 gallons per minute of water from 58°F to 125°F in the test. The median electric tankless model heats 0.7 gallons per minute by 67°F. Of 337 electric tankless models, 91 have a higher flow than this one.

In tests, 94% of the energy went to hot water, so its UEF is 0.94. In the test, daily hot water use was set to very small (its draw pattern). Of 272 electric tankless models with the same draw pattern, 187 have a higher UEF and 55 a lower one. On its draw pattern, the median electric tankless UEF is 0.96. Of the energy it spends heating water, 98% ends up in it (its recovery efficiency).

There is one more basic model with the same test figures. The brand name on that one is State.

Also listed as

They carry every figure in the table above.

Updated Oct 26, 2026 · Methodology