GE GE27DNHPDG01
GE GE27DNHPDG01 is in the DOE listing as of Oct 26, 2026.
It has a certified UEF of 0.91 and a certified flow of 2.7 gal/min at a 67°F rise.
Its certified flow is 2.7 gal/min at a 67°F rise, while GE advertises 5.4 gal/min at the temperatures it states (Read Oct 5, 2026), so a comparison at the same rise is not possible.
- Electric tankless water heater
- 1 listed model
ENERGY STAR certification does not cover this type of water heater.
Certified and advertised figures
- Flow at a 67°F rise
- 2.7gallons per minuteCertified
- Advertised flow
- 5.4gallons per minuteGE, at the temperatures it states
- UEF
- 0.91Uniform energy factor
Your fixtures at once
Change your hour and flowFlow where you live
The heater gives less flow when colder incoming water needs a bigger rise.
- Cold water
- Cold water must be at least 10°F colder than the hot water setting.
- Flow estimate
- The estimate uses the lowest certified flow among the listed models. It is about 2.6 gal/min at a 70°F rise.
Flow limits
- The estimate excludes the flow needed to turn the heater on, heat lost in pipes, and installation.
- Cold water from a well or long pipe run can differ from the temperature you enter.
- Without a stated flow limit, estimates for warmer water may exceed the heater’s actual flow.
Advertised and certified figures
| Figure | Advertised | Certified | Advertiser | Read |
|---|---|---|---|---|
| UEF | 0.91 | 0.91 | GE | Read Oct 5, 2026 |
| Flow | 5.4 gal/min at the temperatures it states | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 6.19 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 5.4 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 5.09 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 4.4 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 4.19 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 3.79 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 3.4 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 3.29 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
| Flow | 3.0 gal/min, no rise stated | 2.7 gal/min at a 67°F rise | GE | Read Oct 5, 2026 |
Certified figures by listed model
| Model number | UEF | Flow at a 67°F rise (gal/min) | Recovery efficiency | Draw pattern |
|---|---|---|---|---|
| GE27DNHPDG01 | 0.91 | 2.7 | 98% | — |
UEF is the uniform energy factor. A dash means the model has no such figure.
It warms 2.7 gallons per minute of water from 58°F to 125°F in the test. The median electric tankless model heats 0.7 gallons per minute by 67°F. Of 337 electric tankless models, 11 have a higher flow than this one.
In tests, 91% of the energy went to hot water, so its UEF is 0.91. Of the energy it spends heating water, 98% ends up in it (its recovery efficiency).
- Every GE basic model
- Every electric tankless water heater certified at 2.0 gallons per minute or more
- Every electric tankless water heater
Not covered
- Changes to an advertised figure after the date beside it.