Rheem RTG-95XLN-3

Rheem RTG-95XLN-3 is in the DOE listing as of Oct 26, 2026.

It has a certified UEF of 0.82 and a certified flow of 4.8 gal/min at a 67°F rise.

Its certified flow is 4.8 gal/min at a 67°F rise, while Rheem advertises 9.5 gal/min, no rise stated (Read Oct 4, 2026), so a comparison at the same rise is not possible.

  • Gas tankless water heater
  • 8 listed models

Not listed as ENERGY STAR certified on Oct 26, 2026.

Certified and advertised figures

Flow at a 67°F rise
4.8gallons per minuteCertified
Advertised flow
9.5gallons per minuteRheem, no rise stated
UEF
0.82Uniform energy factor

Flow where you live

The heater gives less flow when colder incoming water needs a bigger rise.

Cold water
Cold water must be at least 10°F colder than the hot water setting.
Flow estimate
The estimate uses the lowest certified flow among the listed models. It is about 4.6 gal/min at a 70°F rise.

Flow limits

  • The estimate excludes the flow needed to turn the heater on, heat lost in pipes, and installation.
  • Cold water from a well or long pipe run can differ from the temperature you enter.
  • Without a stated flow limit, estimates for warmer water may exceed the heater’s actual flow.

Advertised and certified figures

Rheem RTG-95XLN-3: advertised and certified
Rheem RTG-95XLN-3: advertised and certified UEF: advertised 0.82, certified 0.82. Flow: advertised 9.5 gal/min, certified 4.8 gal/min (advertised no rise stated, certified at a 67°F rise). Flow: advertised 9.5 gal/min, certified 4.8 gal/min (advertised at a 35°F rise, certified at a 67°F rise). Flow: advertised 7.4 gal/min, certified 4.8 gal/min (advertised at a 45°F rise, certified at a 67°F rise). UEF Advertised 0.82 Certified 0.82 Flow · advertised no rise stated, certified at a 67°F rise Advertised 9.5 gal/min Certified 4.8 gal/min Flow · advertised at a 35°F rise, certified at a 67°F rise Advertised 9.5 gal/min Certified 4.8 gal/min Flow · advertised at a 45°F rise, certified at a 67°F rise Advertised 7.4 gal/min Certified 4.8 gal/min
Rheem RTG-95XLN-3: advertised figures, where and when read
FigureAdvertisedCertifiedAdvertiserRead
UEF 0.82 0.82 The Home Depot Archived copy, Jan 10, 2024
Flow 9.5 gal/min, no rise stated 4.8 gal/min at a 67°F rise Rheem Read Oct 4, 2026
Flow 9.5 gal/min at a 35°F rise 4.8 gal/min at a 67°F rise The Home Depot Archived copy, Jan 10, 2024
Flow 7.4 gal/min at a 45°F rise 4.8 gal/min at a 67°F rise The Home Depot Archived copy, Jan 10, 2024
Flow 6.0 gal/min at a 55°F rise 4.8 gal/min at a 67°F rise The Home Depot Archived copy, Jan 10, 2024
Flow 5.0 gal/min at a 65°F rise 4.8 gal/min at a 67°F rise The Home Depot Archived copy, Jan 10, 2024

See how advertised flow compares across tankless models

Certified figures by listed model

Rheem RTG-95XLN-3: certified figures by listed model
Model numberUEFFlow at a 67°F rise (gal/min)Recovery efficiencyDraw pattern
ECO200XELN-30.824.884%High
ECO200XELP-30.824.884%High
RTG-95XELN-30.824.884%High
RTG-95XELP-30.824.884%High
RTG-95XLN-30.824.884%High
RTG-95XLP-30.824.884%High
RTG-R95XELN-30.824.884%High
RTG-R95XELP-30.824.884%High

UEF is the uniform energy factor. A dash means the model has no such figure.

It heats 4.8 gallons per minute of water by 67°F in the test. The median flow among gas tankless models is 4.8 gallons per minute. Its flow at a 67°F rise trails 221 of the 487 gas tankless models.

On Oct 26, 2026, this heater was not listed as ENERGY STAR certified. In the test, 18% of its energy does not reach the hot water (UEF 0.82). Its test simulated a day of high hot water use (its draw pattern). Its UEF is lower than that of 243 of the 399 gas tankless models with its draw pattern. On its draw pattern, the median gas tankless UEF is 0.93. When it runs, 84% of the energy it uses reaches the water (its recovery efficiency).

A tag or quote may show any of its 8 model numbers. There are 4 more basic models with the same test figures. Each of them is listed under a different brand.

In one state, one rebate program may accept it if it meets their other terms.

Also listed as

They carry every figure in the table above.

Rebates

Rheem RTG-95XLN-3: rebate programs
ProgramStateStatusProgram page
SoCalGas High-Efficiency or ENERGY STAR Certified Natural Gas Tankless Water Heaters rebate CA May qualify if it meets the other terms Its own page

Programs change their terms. Check the program's own page before you buy.

Updated Oct 26, 2026 · Methodology

Not covered

  • Changes to an advertised figure after the date beside it.