Richmond RTGH-84DVLN-3
Richmond RTGH-84DVLN-3 is in the DOE listing as of Oct 19, 2026.
- Gas tankless water heater
- 2 listed models
Not listed as ENERGY STAR certified on Oct 19, 2026.
Its figures are also listed under Rheem RTGH-84DVLN-3.
Certified and advertised figures
- Flow at a 67°F rise
- 4.5gallons per minuteCertified
- Advertised flow
- 8.4gallons per minuteRichmond, at a 35°F rise
- UEF
- 0.93Uniform energy factor
Your fixtures at once
Change your hour and flowFlow where you live
The heater gives less flow when colder incoming water needs a bigger rise.
- Cold water
- Cold water must be at least 10°F colder than the hot water setting.
- Flow estimate
- The estimate uses the lowest certified flow among the listed models. It is about 4.3 gal/min at a 70°F rise.
Flow limits
- The estimate excludes the flow needed to turn the heater on, heat lost in pipes, and installation.
- Cold water from a well or long pipe run can differ from the temperature you enter.
- Without a stated flow limit, estimates for warmer water may exceed the heater’s actual flow.
Advertised and certified figures
| Figure | Advertised | Certified | Advertiser | Read |
|---|---|---|---|---|
| UEF | 0.93 | 0.93 | Richmond | Read Oct 5, 2026 |
| Flow | 8.4 gal/min at a 35°F rise | 4.5 gal/min at a 67°F rise | Richmond | Read Oct 5, 2026 |
| Flow | 6.7 gal/min at a 45°F rise | 4.5 gal/min at a 67°F rise | Richmond | Read Oct 5, 2026 |
| Flow | 4.6 gal/min at a 67°F rise | 4.5 gal/min at a 67°F rise | Richmond | Read Oct 5, 2026 |
Certified figures by listed model
| Model number | UEF | Flow at a 67°F rise (gal/min) | Recovery efficiency | Draw pattern |
|---|---|---|---|---|
| RMTGH84DVLN-3 | 0.93 | 4.5 | 94% | High |
| RMTGH84DVLP-3 | 0.93 | 4.5 | 94% | High |
UEF is the uniform energy factor. A dash means the model has no such figure.
At a 67°F rise, its flow in the test is 4.5 gallons per minute. The median flow among gas tankless models is 4.8 gallons per minute. Its flow at a 67°F rise trails 319 of the 487 gas tankless models.
As of Oct 19, 2026, it was not listed as ENERGY STAR certified. In tests, 93% of the energy it uses ends up as hot water (UEF 0.93). Its test ran at the high level of daily hot water use. Of 399 gas tankless models with the same draw pattern, 196 have a higher UEF and 179 a lower one. Its UEF is the median for its type and draw pattern. Of the energy it spends heating water, 94% ends up in it (its recovery efficiency).
It is sold as RMTGH84DVLN-3 and RMTGH84DVLP-3. There are 3 more basic models with the same test figures. The Friedrich, Rheem, and Ruud brands list one or more of them. For the full group, see the Rheem RTGH-84DVLN-3 page.
It may qualify for 2 rebate programs. Another 2 programs may accept it if it meets their other terms.
Also listed as
They carry every figure in the table above.
Rebates
| Program | State | Status | Program page |
|---|---|---|---|
| SoCalGas High-Efficiency or ENERGY STAR Certified Natural Gas Tankless Water Heaters rebate | CA | May qualify if it meets the other terms | Its own page |
| Xcel Energy MINNESOTA RESIDENTIAL ENERGY EFFICIENCY PROGRAMS (gas storage, gas tankless) | MN | May qualify | Its own page |
| PSE&G Tankless Water Heaters | NJ | May qualify | Its own page |
| Focus on Energy (gas tankless) | WI | May qualify if it meets the other terms | Its own page |
Programs change their terms. Check the program's own page before you buy.
- Every Richmond basic model
- Every gas tankless water heater certified at 4.0 to 4.9 gallons per minute
- Every gas tankless water heater
- The most-searched gas tankless models side by side
Not covered
- Changes to an advertised figure after the date beside it.