A. O. Smith HPTV-50 2**
A. O. Smith HPTV-50 2** is in the DOE listing as of Oct 26, 2026 and is in the ENERGY STAR list as of Oct 26, 2026.
It has a labeled size of 50 gallons, a certified storage volume of 46 gallons, a certified UEF of 3.00, and a certified first-hour rating of 52 gallons of hot water.
Its advertised UEF of 3.00 from A. O. Smith matches the certified 3.00 (Read Oct 4, 2026).
- Heat pump water heater
- 2 listed models
Certified figures
- Storage volume
- 46gallons
- UEF
- 3.00Uniform energy factor
- First-hour rating
- 52gallonsHot water in the first hour
Your busiest hour
Change your hourAdvertised and certified figures
| Figure | Advertised | Certified | Advertiser | Read |
|---|---|---|---|---|
| Size | 50 gal, nominal size | 46 gal storage volume | A. O. Smith | Read Oct 4, 2026 |
| Size | 46 gal | 46 gal storage volume | A. O. Smith | Read Oct 4, 2026 |
| UEF | 3.00 | 3.00 | A. O. Smith | Read Oct 4, 2026 |
| First-hour rating | 52 gal | 52 gal | A. O. Smith | Read Oct 4, 2026 |
Certified figures by listed model
| Model number | Storage volume (gal) | UEF | First-hour rating (gal) | Recovery efficiency | Draw pattern |
|---|---|---|---|---|---|
| HPTV-50 2** | 46 | 3.00 | 52 | 457% | Medium |
| HPV10-50H01DV 2** | 46 | 3.00 | 52 | 457% | Medium |
UEF is the uniform energy factor. A dash means the model has no such figure.
ENERGY STAR certified models
| Model number | Storage volume (gal) | UEF | First-hour rating (gal) | Recovery efficiency |
|---|---|---|---|---|
| HPTV-50 2** | 46 | 3.00 | 52 | 457% |
| HPV10-50H01DV 2** | 46 | 3.00 | 52 | 457% |
It holds 46 gallons in the test, 4 gallons less than its 50-gallon sold size. It delivers 52 gallons of hot water in the test's first hour. That is 6 gallons more than its tank holds, since it reheats during the hour. Of 481 heat pump models, 439 give more hot water in the first hour. The median heat pump model gives 72 gallons in the first hour of the test.
All 2 of its model numbers are ENERGY STAR certified. For each unit of energy it uses, 3.00 units end up in the hot water (its UEF). It moves heat from the air rather than making it, so its UEF passes 1. Its test simulated a day of medium hot water use (its draw pattern). Its UEF is lower than that of 208 of the 226 heat pump models with its draw pattern. On its draw pattern, the median heat pump UEF is 3.68. When it reheats water in the test, the water gains 457% of the energy it uses.
It is the basic model for HPTV-50 2** and HPV10-50H01DV 2**. All of its test figures are shared by 4 other basic models. Each of the 4 other brands lists one of them.
It may qualify for 19 rebate programs in 20 states. Another 5 rebate programs may accept it if it meets their other terms.
Also listed as
They carry every figure in the table above.
Rebates
Programs change their terms. Check the program's own page before you buy.
- Every A. O. Smith basic model
- Every 50-gallon heat pump water heater
- Every heat pump water heater
- The most-searched heat pump models side by side
Not covered
- Changes to an advertised figure after the date beside it.