Hot Water List

American GCR-30R 4**

American GCR-30R 4** is in the DOE listing as of Oct 26, 2026.

  • Gas storage water heater
  • 2 listed models

Not listed as ENERGY STAR certified on Oct 26, 2026.

Its figures are also listed under A. O. Smith GCR-30R 4**.

Certified figures

Storage volume
29gallons
UEF
0.60Uniform energy factor
First-hour rating
62gallonsHot water in the first hour

Advertised and certified figures

American GCR-30R 4**: advertised and certified
American GCR-30R 4**: advertised and certified Size: advertised 30 gal, certified 29 gal (advertised nominal size, certified storage volume). Size: advertised 29 gal, certified 29 gal (certified storage volume). UEF: advertised 0.60, certified 0.60. First-hour rating: advertised 62 gal, certified 62 gal. Size · advertised nominal size, certified storage volume Advertised 30 gal Certified 29 gal Size · certified storage volume Advertised 29 gal Certified 29 gal UEF Advertised 0.60 Certified 0.60 First-hour rating Advertised 62 gal Certified 62 gal
American GCR-30R 4**: advertised figures, where and when read
FigureAdvertisedCertifiedAdvertiserRead
Size 30 gal, nominal size 29 gal storage volume American Read Oct 4, 2026
Size 29 gal 29 gal storage volume American Read Oct 4, 2026
UEF 0.60 0.60 American Read Oct 4, 2026
First-hour rating 62 gal 62 gal American Read Oct 4, 2026

Certified figures by listed model

American GCR-30R 4**: certified figures by listed model
Model numberStorage volume (gal)UEFFirst-hour rating (gal)Recovery efficiencyDraw pattern
G62-30T32R 4**290.606273%Medium
G62-30T32R 4*1290.606273%Medium

UEF is the uniform energy factor. A dash means the model has no such figure.

It holds 29 gallons in the test, 1 gallon less than its 30-gallon sold size. It delivers 62 gallons of hot water in the test's first hour. Its tank holds 29 gallons, so reheating adds 33 gallons during the first hour. Among 763 gas storage models, 671 have a higher first-hour rating. The median gas storage model gives 78 gallons in the first hour of the test.

On Oct 26, 2026, this heater was not listed as ENERGY STAR certified. In the test, 40% of its energy does not reach the hot water (UEF 0.60). Its test ran at the medium level of daily hot water use. Among 288 gas storage models on its draw pattern, 88 have a higher UEF. For its type and draw pattern, its UEF sits at the median. When it reheats water in the test, 73% of the energy it uses ends up in the water.

It is the basic model for G62-30T32R 4** and G62-30T32R 4*1. All of its test figures are shared by 5 other basic models. Each of the 5 other brands lists one of them. For the full group, see the A. O. Smith GCR-30R 4** page.

Also listed as

They carry every figure in the table above.

Updated Oct 26, 2026 · Methodology

Not covered

  • Changes to an advertised figure after the date beside it.