Lochinvar TK-310C-NI 1**
Lochinvar TK-310C-NI 1** is in the DOE listing as of Oct 19, 2026.
- Gas tankless water heater
- 1 listed model
Not listed as ENERGY STAR certified on Oct 19, 2026.
Its figures are also listed under A. O. Smith TK-310C-NI 1**.
Certified and advertised figures
- Flow at a 67°F rise
- 4.6gallons per minuteCertified
- Advertised flow
- 8.0gallons per minuteLochinvar, up to, no rise stated
- UEF
- 0.81Uniform energy factor
Your fixtures at once
Change your hour and flowFlow where you live
Colder incoming water needs a bigger rise, so the heater gives less flow.
- Cold water
- Cold water must be at least 10°F colder than the hot water setting.
- Flow estimate
- The estimate uses the lowest certified flow among the listed models. It is about 4.4 gal/min at a 70°F rise.
Flow limits
- The estimate excludes the flow needed to turn the heater on, heat lost in pipes, and installation.
- Cold water from a well or long pipe run can differ from the temperature you enter.
- Without a stated flow limit, estimates for warmer water may exceed the heater’s actual flow.
Advertised and certified figures
| Figure | Advertised | Certified | Advertiser | Read |
|---|---|---|---|---|
| UEF | 0.81 | 0.81 | Lochinvar | Read Oct 4, 2026 |
| UEF | up to 0.81 | 0.81 | Lochinvar | Read Oct 4, 2026 |
| Flow | up to 8.0 gal/min, no rise stated | 4.6 gal/min at a 67°F rise | Lochinvar | Read Oct 4, 2026 |
| Flow | 4.6 gal/min at a 67°F rise | 4.6 gal/min at a 67°F rise | Lochinvar | Read Oct 4, 2026 |
Certified figures by listed model
| Model number | UEF | Flow at a 67°F rise (gal/min) | Recovery efficiency | Draw pattern |
|---|---|---|---|---|
| LTI-310C 1** | 0.81 | 4.6 | 85% | High |
UEF is the uniform energy factor. A dash means the model has no such figure.
At a 67°F rise, its flow in the test is 4.6 gallons per minute. The median gas tankless model heats 4.8 gallons per minute by 67°F. Among 487 gas tankless models, 300 give more flow at a 67°F rise.
It was not listed as ENERGY STAR certified on Oct 19, 2026. In tests, 81% of the energy it uses ends up as hot water (UEF 0.81). Its test simulated a day of high hot water use (its draw pattern). Of 399 gas tankless models with the same draw pattern, 327 have a higher UEF. On its draw pattern, the median gas tankless UEF is 0.93. Of the energy it spends heating water, 85% ends up in it (its recovery efficiency).
There are 5 more basic models with the same test figures. Each of them is listed under a different brand. For the full group, see the A. O. Smith TK-310C-NI 1**.
Also listed as
They carry every figure in the table above.
- Every Lochinvar basic model
- Every gas tankless water heater certified at 4.0 to 4.9 gallons per minute
- Every gas tankless water heater
- The most-searched gas tankless models side by side
Not covered
- Changes to an advertised figure after the date beside it.