State HPTU-50N 1**
State HPTU-50N 1** is in the DOE listing as of Oct 22, 2026. State HPTU-50N 1** is in the ENERGY STAR list as of Oct 22, 2026.
- Heat pump water heater
- 3 listed models
Its figures are also listed under A. O. Smith HPTU-50N 1**.
Certified figures
- Storage volume
- 46gallons
- UEF
- 3.45Uniform energy factor
- First-hour rating
- 66gallonsHot water in the first hour
Your busiest hour
Change your hourAdvertised and certified figures
| Figure | Advertised | Certified | Advertiser | Read |
|---|---|---|---|---|
| Size | 50 gal, nominal size | 46 gal storage volume | State | Read Oct 4, 2026 |
| Size | 46 gal | 46 gal storage volume | State | Read Oct 4, 2026 |
| UEF | 3.45 | 3.45 | State | Read Oct 4, 2026 |
| First-hour rating | 66 gal | 66 gal | State | Read Oct 4, 2026 |
Certified figures by listed model
| Model number | Storage volume (gal) | UEF | First-hour rating (gal) | Recovery efficiency | Draw pattern |
|---|---|---|---|---|---|
| HPX-50-DHPTCTA 1** | 46 | 3.45 | 66 | 407% | Medium |
| HPX-50-DHPTDR 1** | 46 | 3.45 | 66 | 407% | Medium |
| HPX-50-DHPTNE 1** | 46 | 3.45 | 66 | 407% | Medium |
UEF is the uniform energy factor. A dash means the model has no such figure.
ENERGY STAR certified models
| Model number | Storage volume (gal) | UEF | First-hour rating (gal) | Recovery efficiency |
|---|---|---|---|---|
| HPX-50-DHPTCTA 1** | 46 | 3.45 | 66 | 407% |
| HPX-50-DHPTNE 1** | 46 | 3.45 | 66 | 407% |
It holds 46 gallons in the test, 4 gallons less than its 50-gallon sold size. It delivers 66 gallons of hot water in the test's first hour. Reheating lets it give 20 gallons beyond the 46 gallons in its tank. Of 481 heat pump models, 330 give more hot water in the first hour. The median heat pump model gives 72 gallons in its first hour.
Of its 3 model numbers, 2 are ENERGY STAR certified. In the test, it gives 3.45 units of hot water energy per unit it uses (its UEF). A UEF above 1 is possible because it moves heat from the air into the water. In the test, daily hot water use was set to medium (its draw pattern). Of 226 heat pump models with the same draw pattern, 185 have a higher UEF. On its draw pattern, the median heat pump UEF is 3.68. While it reheats, the water gains 407% of the energy it uses (its recovery efficiency).
It is the basic model for HPX-50-DHPTCTA 1**, HPX-50-DHPTDR 1**, and HPX-50-DHPTNE 1**. Its test figures match those of 5 other basic models. They are listed under 5 other brands, one each. You can find the whole group on the page for the A. O. Smith HPTU-50N 1**.
It may qualify for 21 rebate programs in 20 states. It may qualify for 7 more if it meets terms its figures do not show.
Also listed as
They carry every figure in the table above.
Rebates
Programs change their terms. Check the program's own page before you buy.
- Every State basic model
- Every 50-gallon heat pump water heater
- Every heat pump water heater
- The most-searched heat pump models side by side
Not covered
- Changes to an advertised figure after the date beside it.