Hot Water List

American ENT-50-1**

American ENT-50-1** is in the DOE listing as of Oct 19, 2026.

  • Electric storage water heater
  • 13 listed models

ENERGY STAR certification does not cover this type of water heater.

Its figures are also listed under A. O. Smith ENT-50-1**.

Certified figures

Storage volume
46gallons
UEF
0.92Uniform energy factor
First-hour rating
62gallonsHot water in the first hour

Advertised and certified figures

American ENT-50-1**: advertised and certified
American ENT-50-1**: advertised and certified Size: advertised 50 gal, certified 46 gal (advertised nominal size, certified storage volume). Size: advertised 46 gal, certified 46 gal (certified storage volume). UEF: advertised 0.92, certified 0.92. First-hour rating: advertised 62 gal, certified 62 gal. Size · advertised nominal size, certified storage volume Advertised 50 gal Certified 46 gal Size · certified storage volume Advertised 46 gal Certified 46 gal UEF Advertised 0.92 Certified 0.92 First-hour rating Advertised 62 gal Certified 62 gal
American ENT-50-1**: advertised figures, where and when read
FigureAdvertisedCertifiedAdvertiserRead
Size 50 gal, nominal size 46 gal storage volume American Read Oct 4, 2026
Size 46 gal 46 gal storage volume American Read Oct 4, 2026
UEF 0.92 0.92 American Read Oct 4, 2026
First-hour rating 62 gal 62 gal American Read Oct 4, 2026

Certified figures by listed model

American ENT-50-1**: certified figures by listed model
Model numberStorage volume (gal)UEFFirst-hour rating (gal)Recovery efficiencyDraw pattern
E10N-50H 1**460.926298%Medium
E10N-50H-1**460.926298%Medium
E6N-50H 1**460.926298%Medium
E6N-50H-1**460.926298%Medium
E8N-50H 1**460.926298%Medium
E8N-50H-1**460.926298%Medium
LDCE32-40R-030DV 1**460.926298%Medium
LDCE32-40R-040DV 1**460.926298%Medium
LDCE32-40R-045DV 1**460.926298%Medium
LDCE32-40R-050DV 1**460.926298%Medium
LDCE32-40R-055DV 1**460.926298%Medium
LDCE32-40R-060DV 1**460.926298%Medium
NE3F50HD 1**460.926298%Medium

UEF is the uniform energy factor. A dash means the model has no such figure.

It holds 46 gallons in the test, 4 gallons less than its 50-gallon sold size. It delivers 62 gallons of hot water in the test's first hour. That is 16 gallons more than its tank holds, since it reheats during the hour. Among 477 electric storage models, 124 have a higher first-hour rating. The median electric storage model gives 55 gallons in the first hour of the test.

In tests, 92% of the energy went to hot water, so its UEF is 0.92. Its test simulated a day of medium hot water use (its draw pattern). Of 297 electric storage models with the same draw pattern, 81 have a higher UEF and 2 a lower one. Its UEF is the median for its type and draw pattern. Of the energy spent to reheat water, 98% goes into it (its recovery efficiency).

A tag or quote may show any of its 13 model numbers. All of its test figures are shared by 5 other basic models. Each of the 5 other brands lists one of them. For the full group, see the A. O. Smith ENT-50-1** page.

Also listed as

They carry every figure in the table above.

Updated Oct 19, 2026 · Methodology

Not covered

  • Changes to an advertised figure after the date beside it.